ARI-TEMPTROL® 775 LCG

Thermal-opening valve – straight through with flanges without cooling spacer (max. 130°C) – without balancing bellow

ARI-TEMPTROL® 775 LCG Thermal-opening valve - straight through with flanges without cooling spacer (max. 130°C) - without balancing bellow
eClass-No.: 37012290
Application: Industrial heating and ventilation systems, residential applications, marked-warehouses, ship building, cooling systems, etc.
Medium: Fluids, air and steam

• Self-operating (no auxilary power required)
• Reliable, low maintenance operation
• Over-temperature safety device
• Valves pressure balanced with stainless steel bellows
• 3 thermal controller sizes for optimal selection of proportional range
• Thermal sensors with different time constants
• Exact and easy adjustment
• Setting range is adjustable
• Sensor pocket
• Manual control device

Thermal-opening valve – straight through with flanges

ARI-TEMPTROL® 775 Thermal-opening valve - straight through with flanges without cooling spacer (max. 150°C)

Fig. …775 max. 150°C (> 150°C on request)

Figure Nominal pressure Material Nominal diameter
12.775 PN16 EN-JL1040 DN15-100
22.775 PN16 EN-JS1049 DN15-100
23.775 PN25 EN-JS1049 DN15-100
35.775 PN40 1.0619+N DN15-100
55.775 PN40 1.4408 DN15-100

Construction LC without balanced bellow

Figure Nominal pressure Material Nominal diameter
12.775….1..1 PN16 EN-JL1040 DN15-50
ARI-TEMPTROL® 775 Thermal-opening valve - straight through with flanges without cooling spacer (max. 150°C)

Fig. 12.775….1..1 max. 130°C (> 130°C on request)

DN 15 20 25 32 40 50 65 80 100
Face-to-face dimension FTF series 1 according to DIN EN 558 Standard-flange dimensions refer to page 15.
L (mm) 130 150 160 180 200 230 290 310 350
Dimensions
Fig. 775 H (mm) 195 195 200 225 245 280 300 365 385
Fig. 775….1..1 (LC) H (mm) 125 125 130 155 160 160
Weights
Fig. 775 (kg) 5,4 6,8 9,1 11,9 17 19,5 30 37 385
Fig. 775….1..1 (LC) (kg) 4,5 6 8 10,5 15 17
Kvs-value
Standard Kvs-value (m3/h) 4,0 6,3 10,0 16,0 22,0 32,0 50,0 70,0 80,0
Travel (mm) 7,5 7,5 8 9,5 9,5 11,5 14 15 15
Reduced Kvs-value (m3/h) 1,0
Travel (mm) 5
Leakage rate IV acc. to DIN EN 1349 or DIN EN 60534-4 (≤ 0,01% from the nominal flow)
Max. differential pressure drop Δp
Fig. 775 A AB

Straight through

(bar) 12 4 4 4 4 4 4 4 4
Fig. 775….1..1 (LC) A AB

Straight through

(bar) 3 3 2,5 1,5 1 0,5
Pressure balancing of the actuator needed at P1 > max. differential pressure drop Δp (out of table). For pressure balancing use manual control device (Type 9900390011).
Parts
Pos. Sp.p. Description Fig. 12.775 Fig. 22./23.775 Fig. 35.775 Fig. 55.775
1 Body EN-JL1040, EN-GJL-250 EN-JS1049,

EN-GJS-400-18U-LT

GP240GH+N, 1.0619+N GX5CrNiMo19-11-2, 1.4408
1.2 Seat X20Cr13+QT, 1.4021+QT X6CrNiMoTi17-12-2, 1.4571
3 Cheese head screw A2-70
4 x Plug guiding X20Cr13+QT, 1.4021+QT X6CrNiTi18-10, 1.4541
5 Giude bushing X20Cr13+QT, 1.4021+QT X6CrNiTi18-10, 1.4541
7 x Gasket Graphite
11 Bonnet EN-JS1049, EN-GJS-400-18U-LT GX5CrNiMo19-11-2, 1.4408
14 x Spindle unit X20Cr13+QT, 1.4021+QT / X6CrNiTi18-10, 1.4541 X6CrNiTi18-10, 1.4541
19 Bearing cover X6CrNiTi18-10, 1.4541
21 Hexagon nut A2-70
23 Hexagon nut C35E, 1.1181 -A2B A4-70
24 Hexagon screw 5.6-A2B A4-70
25 Flange S235JR, 1.0037 X6CrNiTi18-10, 1.4541
26 x Gasket Graphite (with CrNi-expanded metal insert)
28 Cooling spacer EN-JS1049, EN-GJS-400-18U-LT X6CrNiTi18-10, 1.4541
37 x Compression spring X12CrNi17-7, 1.4310
55 x Balanced bellow X6CrNiTi18-10, 1.4541
└ Spare parts

Information / restriction of technical rules need to be observed!

Operating and installation instructions can be downloaded at www.ari-armaturen.com. ARI-Valves of EN-JL1040 are not allowed to be operated in systems acc. to TRD 110.

A production permission acc. to TRB 801 No. 45 is available (acc. to TRB 801 No. 45 EN-JL1040 is not allowed.) The engineer, designing a system or a plant, is responsible for the selection of the correct valve.

Resistance and fitness must be verified (contact manufacturer for information, refer to Product overview and Resistance list).

©2022 PT. TOTALITAS TEKNIK INDONESIA. All Rights Reserved.