AMC3200 Series

Converter For Electromagnetic Flowmeter Model AMC3200 Series

AMC3200 Series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors.
The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.
It’s equipped with bluetooth, HART and MODBUS communication functions.

  • Four line LCD display Flow Rate / Energy / Totalizer / Temperature
  • +/-0.2% value of reading
  • Bi-direction flow measurement, and the display can rotate
  • With hourly report, daily report, monthly report and yearly report
  • query function
  • 99 times / dates records for alarm
  • 99 (total) times records for power on / off
  • MODBUS, Bluetooth, BACnet protocol
Excitation DC pulsed
Display 3 Lines LCD with illumination

Line 1:
9 Digit totalizer for forward flow
9 Digit totalizer for reverse flow
9 Digit totalizer for difference

Line 2:
5 Digit flowrate / velocity / % / mA / Hz

Line 3:
Parameter / Query / Clr tot / Query LOG
Alarm, Guidance

Totalizer Unit:
t, kg, g, lb, Ston, Lton, m3, L, mL, Igal, gal, Mgal, bbl, ft3, a-ft

Time Unit:
sec, min, hour, day

Measuring Range Min. 0-0.15 m/s
Max. 0-15 m/s
Accuracy +/-0.2% of reading (Velocity≥0.5 m/s)
+/-0.001 m/s (Velocity<0.5 m/s)<0.5 m/s)
Repeatability +/-0.05% of reading
Current Output 4-20 mA (Isolated)
Load: Max. 600 Ω
Pulse Output Open collector
Rating: 3-30 VDC, 50 mA Max.
Pulse Rate 1) Scaled pulse (mL/Pulse, L/Pulse, Other)
2) Frequency: 0-5000 Hz
Pulse Width 50% of band width
Alarm High / Low with open collector output
Rating: 3-30 VDC, 50 mA Max.
Communication Bluetooth (Android) Standard
RS485 (MODBUS Protocol) Standard
HART signal (Compatible) Optional
Keypad 3 Internal keys for programming and display control
Data Storage Operation parameters and totalizer figures are stored by EEPROM for more than 10 years
Low Flow Cut-off 0-9.9%
Damping 0.1-99.9 s
Density Setting 0.1-9.99 g/cm3
Self Diagnosis The following error messages are displayed if failure occurs
– Abnormal sample
– Pulse width
– Overanged output
– Internal error
– Overflow
– Empty pipe
Cable Entry Standard: M20
Option: 1/2″ NPTF
Protection Class IP67, Explosion Proof, Ex d ia [ia] q llC T6
Ambient Temperature -25-65 oC
Material Aluminium Alloy
Power Supply 90-260 VAC, 50/60 Hz
24 VDC +/-10% (Option)
Power Consumption 3-17 W (Dependent on sensor size)
Weight 4.5 kg
Mounting Bracket on 2″ pipe

ALIAMAG AMC3200 Series, Electromagnetic Flowmeter Alia AMC3200, Converter for Electromagnetic Flowmeter, AMC3200 – Bluetooth, HART Electromagnetic Flowmeter, Alia Electromagnetic Flow Meter model AMC3200, Converter For Electromagnetic Flowmeter Model AMC3200 Series, Flowmeter Electromagnetic Alia AMC 3200 Series, Official Indonesian Distributor ALIA Group inc.