The ARL5000 Series is a radar level transmitter particularly suited for non-contact level measurement and is characterized by 26 G high frequency microwave pulse. The measurement can reach the distance of 70 m and is not affected by the influence of noise, vapor, pressure, dust, gas volatilization etc. With excellent anti-interference ability, it can work effectively in harsh environments.
Equipped with a new micro processor and optimized antennas, ARL5000 is more ideal in velocity signal analysis, processing capacity,  measurement with stability and accuracy. It is perfect for level measurement control with simple structure and easy installation.

Fitur

  • Anti-interference of noise, vapor, dust, foam, vacuum, etc
  • Shorter wavelength, better reflection on inclined solid surface
  • Non-contact radar, free of wear and pollution
  • Small beam angle & focus energy to enhance anti-inference ability and radar echo
  • High frequency, ideal for the measurement of solid and dielectric constant
  • Measuring distance up to 70 m (230 ft), high accuracy of 3 mm

Spesifikasi

Measure Principle : Radar
Measure Range : 0-70 m
Display : 4 Digit LCD with Bargraph
Resolution : 1 mm / 0.003 ft
Accuracy : +/-3 mm…+/-15 mm
Blind Area : The end of antenna
Beam Angle α : 20° / 18° / 14° / 12° / 8° / 6°
Measuring Interval : >1s (Dependent on configuration setting)
Adjustment Time : >1s (Dependent on configuration setting)
Ambient Temperature : -40~80 °C
Relative Humidity : 0-95% RH
Permittivity DK : >1.4
Ambient Temp. Effect : 3 mm / 10 K, Max. 10 mm
Gas Pressure Effect : 0.22 % (Air: 10 bar / 20 °C)
Material
Antenna : PTFE / PFA / S.S. 316L
Process Connection : PP / PTFE / S.S. 304 / S.S. 316L / S.S +coated
Housing : Aluminum Alloy
Process Connection : 1-1/2″ NPT / G 1-1/2″ Max. : 16 bar
: Flange (DN50-DN150) Max. : 40 bar
: Universal Flange (DN80-DN150) Max. : 3 bar
Protection Class : IP67
: Explosion Proof, Ex d IIC T6
: Intrinsically Safe, Ex ia IIC T6
Keypad : 4 internal keys for programming
Unit : ft, in, m, cm, mm
Process Temperature : -40~130 °C (Standard)
: -40~230 °C (Optional)
Process Pressure : -1.0~40 bar G (Max. )
Max. Cable Length : 8 m (for single cavity housing)
Power Supply : 16-26 VDC (2 wires)
: 24 VDC ± 10% (4 wires)
: 90-253 VAC, 50 / 60 Hz (4 wires)
Power Consumption : 22.5 mA / 1W (Max. )
Current Output : 4-20 mA (2 wires, 4 wires)
Load : Rohm=(VDC-16) * 50
Resolution : 1.6 μA
Alarm Current : No change / 20.5 mA / 22 mA / 3.9 mA
Damping : 0-40 s
Communication : HART signal (Compatible) (Standard)
: RS485 (MODBUS Protocol) (Optional)
Data Storage : Operation parameters and totalization
date are stored by EEPROM for more
than 10 years
EMI / RFI Effect : Follow SAMA PMC 33.1 from 20 to 1000
MHz and for field strengths up to 30 V/m
Vibration Resistance : 20-2000 Hz, 1 (m/s2)2/Hz
Cable Entry : Standard: M20, Option: 1/2″ NPTF