GESTRA NRGT 26-2

Level Transmitter

GESTRA NRGT 26-2 Level Transmitter

Precision Boiler Water Level Monitoring
The GESTRA NRGT 26-2 is an advanced level transmitter designed for continuous monitoring of water levels in steam boilers and other pressurized vessels. Engineered in Germany, this state-of-the-art device provides reliable, real-time water level measurements using capacitance-based technology.

Whether you operate in power plants, chemical processing, or industrial heating systems, the NRGT 26-2 ensures safety, efficiency, and compliance with international standards such as EN 12952 and EN 12953.

Model and mechanical connection
  • NRGT 26-2 Thread G¾ A, EN ISO 228-1, see 7
  • NRGT 26-2s Flange DN 50, PN 40, EN 1092-1, see 8
Nominal pressure rating, admissible service pressure and temperature
  • NRGT 26-2, NRGT 26-2s PN 40          32 bar (abs) at 238 °C
Materials
  • Terminal box 2581 G AlSi12, powder-coated
  • Cover tube 4301 X5 CrNi 18-10
  • Electrode rod insulation PTFE
  • Screw-in body 4571, X6CrNiMoTi17-12-2
NRGT 26-2s:
  • Flange 0460 P250GH
  • Spacer disc PTFE

Max. installed length at 238 °C, all measurements in mm

  • NRGT 26-2
Max. installed length: 373 477 583 688 794 899 1004
Measuring range: 300 400 500 600 700 800 900
Max. installed length: 1110 1214 1319 1423 1528 1636 2156
Measuring range: 1000 1100 1200 1300 1400 1500 2000
  • NRGT 26-2s
Max. installed length: 316 420 526 631 737 842 947 1053
Measuring range: 275 375 475 575 675 775 875 975
Max. installed length: 1157 1262 1366 1471 1579 2099
Measuring range: 1075 1175 1275 1375 1475 1975

Measurement quality

The information below applies to a compensated fluid conductivity range from 0.5 – 10000 µS/cm based on 25 °C.

  • Reading error: ± 1% of set measuring range at the operating point
  • Resolution of reading on display: 1%
  • Resolution for internal processing: 15 bit
  • Resolution of 4-20 mA output: 15 bit
  • Sensitivity (minimum conductivity)
    • Water = 5 µS/cm (see page 8 “Influence of the fluid to be monitored”)
Supply voltage
  • 24 V DC ± 20%
Power consumption
  • 7 W
Current input
  • 0.3 A
Internal fuse
  • T2A
Safety cutout at excessive temperature
  • Cutout occurs when an excessive temperature of 75 °C is measured in the electrode tip
Analogue output
  • 1 x actual value output 4-20 mA, proportional to level, galvanically isolated
  • Maximum output load 500 O
  • M12 connector, 5-pole, A-coded
Indicators and controls
  • 1 x green 4-digit, 7-segment display for showing status information
  • 1 x red LED for indicating an error state
  • 1 x green LED for indicating an OK state
  • 1 x rotary knob IP65 with button for menu navigation and test function

Protection class

  • III Safety Extra Low Voltage (SELV)

IP rating to EN 60529

  • IP 65
Admissible ambient conditions
  • Service temperature: 0 °C – 70 °C
  • Storage temperature: – 40 °C – 80 °C
  • Transport temperature: – 40 °C – 80 °C
  • Air humidity: 10% – 95%           non-condensing
Weight (dependent on length of electrode)
  • NRGT 26-2 1.8 kg (with 300 mm measuring range)
  • NRGT 26-2s 5.9 kg (with 275 mm measuring range)
Admissible installation positions
  • Vertical
  • Oblique to a maximum inclination of 45°. In this case, the length of the electrode rod is limited to 688 mm

©2022 PT. TOTALITAS TEKNIK INDONESIA. All Rights Reserved.