Description
GESTRA NRGT 26-2 Level Transmitter
Precision Boiler Water Level Monitoring
The GESTRA NRGT 26-2 is an advanced level transmitter designed for continuous monitoring of water levels in steam boilers and other pressurized vessels. Engineered in Germany, this state-of-the-art device provides reliable, real-time water level measurements using capacitance-based technology.
Whether you operate in power plants, chemical processing, or industrial heating systems, the NRGT 26-2 ensures safety, efficiency, and compliance with international standards such as EN 12952 and EN 12953.
Technical Data
Model and mechanical connection
- NRGT 26-2 Thread G¾ A, EN ISO 228-1, see 7
- NRGT 26-2s Flange DN 50, PN 40, EN 1092-1, see 8
Nominal pressure rating, admissible service pressure and temperature
- NRGT 26-2, NRGT 26-2s PN 40 32 bar (abs) at 238 °C
Materials
- Terminal box 2581 G AlSi12, powder-coated
- Cover tube 4301 X5 CrNi 18-10
- Electrode rod insulation PTFE
- Screw-in body 4571, X6CrNiMoTi17-12-2
NRGT 26-2s:
- Flange 0460 P250GH
- Spacer disc PTFE
Max. installed length at 238 °C, all measurements in mm
- NRGT 26-2
| Max. installed length: | 373 | 477 | 583 | 688 | 794 | 899 | 1004 |
| Measuring range: | 300 | 400 | 500 | 600 | 700 | 800 | 900 |
| Max. installed length: | 1110 | 1214 | 1319 | 1423 | 1528 | 1636 | 2156 |
| Measuring range: | 1000 | 1100 | 1200 | 1300 | 1400 | 1500 | 2000 |
- NRGT 26-2s
| Max. installed length: | 316 | 420 | 526 | 631 | 737 | 842 | 947 | 1053 |
| Measuring range: | 275 | 375 | 475 | 575 | 675 | 775 | 875 | 975 |
| Max. installed length: | 1157 | 1262 | 1366 | 1471 | 1579 | 2099 |
| Measuring range: | 1075 | 1175 | 1275 | 1375 | 1475 | 1975 |
Measurement quality
The information below applies to a compensated fluid conductivity range from 0.5 – 10000 µS/cm based on 25 °C.
- Reading error: ± 1% of set measuring range at the operating point
- Resolution of reading on display: 1%
- Resolution for internal processing: 15 bit
- Resolution of 4-20 mA output: 15 bit
- Sensitivity (minimum conductivity)
- Water = 5 µS/cm (see page 8 “Influence of the fluid to be monitored”)
Supply voltage
- 24 V DC ± 20%
Power consumption
- 7 W
Current input
- 0.3 A
Internal fuse
- T2A
Safety cutout at excessive temperature
- Cutout occurs when an excessive temperature of 75 °C is measured in the electrode tip
Analogue output
- 1 x actual value output 4-20 mA, proportional to level, galvanically isolated
- Maximum output load 500 O
- M12 connector, 5-pole, A-coded
Indicators and controls
- 1 x green 4-digit, 7-segment display for showing status information
- 1 x red LED for indicating an error state
- 1 x green LED for indicating an OK state
- 1 x rotary knob IP65 with button for menu navigation and test function
Protection class
- III Safety Extra Low Voltage (SELV)
IP rating to EN 60529
- IP 65
Admissible ambient conditions
- Service temperature: 0 °C – 70 °C
- Storage temperature: – 40 °C – 80 °C
- Transport temperature: – 40 °C – 80 °C
- Air humidity: 10% – 95% non-condensing
Weight (dependent on length of electrode)
- NRGT 26-2 1.8 kg (with 300 mm measuring range)
- NRGT 26-2s 5.9 kg (with 275 mm measuring range)
Admissible installation positions
- Vertical
- Oblique to a maximum inclination of 45°. In this case, the length of the electrode rod is limited to 688 mm
GESTRA NRGT 26-2
Level Transmitter
GESTRA: The Ultimate Solution for Industrial Steam & Fluid Control Systems
- GESTRA ORG 12 / ORG 22 Detectors – Oil & Turbidity Sensor for Steam Systems
- Gestra PA 46 Blowdown Valve Rapid Action Boiler Blowdown PA 46
- GESTRA BA 28, 29, 210, 211 PN 63 – 320, DN 25 mm (1″) Reactomat Continuous Blowdown Valves
- GESTRA NRS 1-50 Level Switch
- GESTRA NRR 2-52, 2-53 Level Controller, URB 50 Display Unit
- GESTRA NRG 26-21 Level Monitoring
- GESTRA NRGT 26-2 Level Transmitter
- GESTRA Type 5610 / 5801 Mechanical Pressure Regulators
- GESTRA Clorius Self-acting temperature controllers system
- GESTRA BW 31 / 31A Return-Temperature Control Valve