ARI-PREDEX®

Excess pressure regulator, straight through with diaphragm actuator

ARI-PREDEX® Excess pressure regulator, straight through with diaphragm actuator
eClass-No.: 37010990
Application: Industrial installations, processing technology, plant manufacturing, etc.
Medium: Steam, neutral gases, vapours and liquids, etc.

• Compact design
• Construction without pillars
• Exact and easy adjustment
• Diameter independent ranges
• Simple change of spring and actuator
• 5 exchangeable actuator sizes
• 3 exchangeable spring sizes
• Pressure balanced by stainless steel bellow
• Spindle sealing via stainless steel bellow
• Tapered seat ring
• Screwed seat ring
• Kvs-values reduceable
• Flow divider for noise reduction (optional)
• Plug with PTFE soft sealing (optional)

Excess pressure regulator, straight through with diaphragm actuator UDA

ARI-PREDEX® Excess pressure regulator, straight through with diaphragm actuator

ARI-PREDEX® Excess pressure regulator, straight through with diaphragm actuator

Stainless steel – Actuator


ARI-PREDEX® Excess pressure regulator, straight through with diaphragm actuator

Plug DN 15 – 32


ARI-PREDEX® Excess pressure regulator, straight through with diaphragm actuator

Plug DN 40 – 150


ARI-PREDEX® Excess pressure regulator, straight through with diaphragm actuator

Bellows seal DN 15 – 40

Figure Nominal pressure Material Nominal diameter Inlet pressure ranges Actuator
12.705 PN16 EN-JL1040 DN15-150 0,2 – 16 barg UDA 400 UDA 250 UDA 160 UDA 80 UDA 40
22.705 PN16 EN-JS1049 DN15-150
23.705 PN25 EN-JS1049 DN15-150
34.705 PN25 1.0619+N DN15-150
35.705 PN40 1.0619+N DN15-150
62.705 PN16 1.4581 DN15-150
65.705 PN40 1.4581 DN15-150
Technical data for the actuator refer to page 6.
DN 15 20 25 32 40 50 65 80 100 125 150
Kvs-value
Kvs-value standard (m3/h) 3,2 5 8 12,5 20 32 50 80 125 190 280
reduced (m3/h) 0,1 / 0,4 /

1 / 2,5

0,1 / 0,4 /

1 / 2,5 /

4

0,1 / 0,4 /

1 / 2,5 /

4 / 6,3

Seat-ø (mm) 18 22 25 32 40 50 65 80 100 125 150
Travel (mm) 4 5 6 8 8 10 11 13 16 19 22
Max. differential pressure drop (bar) 16 16 16 16 16 16 16 16 16 16 16
Shutt off class Leakage class I acc. to DIN EN 1349 or DIN EN 60534-4 ( ≤ 0,05% from Kvs-value)
Face-to-face dimension FTF series 1 according to DIN EN 558
L (mm) 130 150 160 180 200 230 290 310 350 400 480
Flanges acc. to DIN EN 1092-1/-2 Flange holes / -thickness tolerances acc. to DIN 2533/2544/2545
ØD PN16 (mm) 95 105 115 140 150 165 185 200 220 250 285
PN25 / 40 (mm) 95 105 115 140 150 165 185 200 235 270 300
ØK PN16 (mm) 65 75 85 100 110 125 145 160 180 210 240
PN25 / 40 (mm) 65 75 85 100 110 125 145 160 190 220 250
n x Ød PN16 (mm) 4 x 14 4 x 14 4 x 14 4 x 18 4 x 18 4 x 18 4 x 18 8 x 18 8 x 18 8 x 18 8 x 22
PN25 / 40 (mm) 4 x 14 4 x 14 4 x 14 4 x 18 4 x 18 4 x 18 8 x 18 8 x 18 8 x 22 8 x 26 8 x 26
Dimensions
H UDA 400 (mm) 545 545 550 550 590 590 595 635 660 700 740
UDA 250 (mm) 505 505 510 510 550 550 555 595 635 660 700
UDA 160 (mm) 485 485 490 490 530 530 535 580 600 640 680
UDA 80 (mm) 485 485 490 490 530 530 535 580 600 640 680
UDA 40 (mm) 485 485 490 490 530 530 535 580 600 640 680
Weights
12.705 /

22./23.705 /

34./35.705

62./65.705

with UDA 400 (kg) 28 29 30 32 37 43 50 73 91 131 164
with UDA 250 (kg) 23 24 25 27 32 38 45 68 88 129 162
with UDA 160 (kg) 21 22 23 25 30 36 43 66 86 127 160
with UDA 80 (kg) 20 21 22 24 29 35 42 65 85 126 159
with UDA 40 (kg) 19 20 21 23 28 34 41 64 84 125 158
Inlet pressure-ranges
  (barg) 0,2 – 0,6 0,5 – 1,2 0,8 – 2,5 2 – 5 4,5 – 10 8 – 16
P-Actuator UDA (cm2) UDA 400 UDA 250 UDA 160 UDA 80 UDA 40
PN-max. (P-Actuator) (barg) 1,6 2,5 6 10 20
Spring end-No. 04 04 07 07 07 10
DN 15 20 25 32 40 50 65 80 100 125 150
Proportional ranges (Combination: actuator with valve in ± bar)
UDA 400 0,2 – 0,6 0,05 0,05 0,05 0,06 0,08 0,10 0,12 0,14 0,17 0,18 0,23
UDA 250 0,5 – 1,2 0,06 0,07 0,09 0,11 0,12 0,15 0,16 0,20 0,25 0,25 0,45
UDA 160 0,8 – 2,5 0,15 0,20 0,25 0,35 0,35 0,40 0,55 0,50 0,65 0,65 0,85
UDA 80 2,0 – 5,0 0,30 0,30 0,45 0,55 0,50 0,65 0,75 0,85 1,05 1,50 1,65
UDA 40 4,5 – 10,0 0,35 0,50 0,70 0,75 0,80 1,05 1,25 1,60 1,70 2,25 2,50
UDA 40 8,0 – 16,0 0,50 0,65 1,05 1,15 1,20 1,50 1,60 1,80 1,90 3,30 3,50
Excess pressure regulators are proportional regulators with permanent control deviation depending from the construction. The actual control deviation depends on the valve load.

(Kv-value / Kvs-value-max) x Proportional range = Actual control deviation The values shown are preliminary values and may vary by the real plant.

Intermediate values for max. permissible operational pressures can be determined by linear Pressure-temperature-ratings interpolation of the given temperature / pressure chart.
acc. to DIN EN 1092-2 -60°C to <-10°C* -10°C to 120°C 150°C 200°C 250°C 300°C 350°C
EN-JL1040 PN16 (bar) 16 14,4 12,8 11,2 9,6
EN-JS1049 PN16 (bar) on request 16 15,5 14,7 13,9 12,8 11,2
EN-JS1049 PN25 (bar) on request 25 24,3 23 21,8 20 17,5
acc. to manufacturers standard -60°C to <-10°C* -10°C to 120°C 150°C 200°C 250°C 300°C 350°C
1.0619+N PN25 (bar) 18,7 25 23,9 22 20 17,2 16
1.0619+N PN40 (bar) 30 40 38,1 35 32 28 25,7
acc. to DIN EN 1092-1 -60°C to <-10°C* -10°C to 120°C 150°C 200°C 250°C 300°C 350°C
1.4581 PN16 (bar) 8 16 15,6 14,9 14,1 13,3 12,8
1.4581 PN40 (bar) 20 40 39,2 37,3 35,4 33,3 32,1

* Studs and nuts made of A4-70 (at temperatures below -10°C)

Application

The excess pressure regulator is a self operated, direct acting proportional regulator, which regulates the upstream pressure.

The upstream pressure (p1) is regulated, this means, the valve opens when the upstream pressure rises over an adjusted set point. If the upstream pressure decreases under the adjusted set point, the valve closes automatically. Because of the stainless steel bellows, the downstream pressure (p2) has no influence.

Operating fields are to regulate fluids of the group II acc. to Pressure Equipment Directive 2014/68/EU, e.g. steam, neutral gases, vapours and liquids. With steam and liquids, having temperatures higher than the allowable working temperatures a water seal pot must be installed in the control line (to protect actuator diaphragm) (refer to page 6).

Installation in the control line can be seen in the system drawing:

ARI-PREDEX® Excess pressure regulator, straight through with diaphragm actuator

Sizing
For the calculation you have the program myValve (Program part PREDEX – Excess pressure regulator). After giving in the process data, the Fig.-No. and size is recommended
out of the integrated data bank. The diameter of the piping in front and behind of the Excess pressure regulator can also be calculated with the max. allowable flow velocities
with myValve.
The necessary upstream pressure gives the needed pressure range. Because the regulation tolerance at the end of the range is smaller, the smaller range must be used, in
case of a range overlapping. For example: upstream pressure 2,4 bar(g), choose actuator range 0,8 – 2,5 bar(g), although 2-5 bar(g) could be used.
The safety valve used to secure the upstream pressure must have an adequate distance between set pressure and upstream pressure. The valve sizing must be done with the
full capacity of the supplying generator (steam generator, compressor, pump, etc.) while the excess pressure regulator is closed. With this found capacity you can, with myValve
(Program part: Safety valves), select the safety valve, and with the exess pressure regulator and other valves, administer them under a project.