The Spirax-Monnier ADV automatic drain valve has been designed to remove condensate from any low points in a compressed air system where automatic drainage should be provided.
Condensate is a mixture of water, oil and dirt, with the thickness or viscosity increasing with low temperatures.

– Variable discharge frequency.
– Variable discharge time.
– Low power comsumption.
– LED showing operational status.
– Reliable, long life, solid state timers.
– Manual test facilities.
– Minimal maintenance.
– Simple installation.

The Spirax-Monnier ADV automatic drain valve can be installed at any low point in a compressed air system where condensate forms or is collected.
These include after coolers, separators, receivers, large filter units and drain legs, etc.
Typical installations are shown on below.

ADV Spirax Monnier Automatic Drain Valve
ADV Spirax Monnier Automatic Drain Valve
ADV Spirax-Monnier Automatic Drain Valve.jpg

¼”, 2″ and ½” screwed BSP.

– Solenoid valve.
– DIN connector.

Operating temperature range Ambient temperature -10 °C > +50 °C
Media temperature -10 °C > +130 °C
Mains voltage/pressure 230 Vac 50 Hz 16 bar
110 Vac 50 Hz 16 bar
120 Vac 60 Hz 16 bar
Discharge time variable 0.5 to 10 seconds
Discharge frequency variable 0.5 to 45 minutes
Connector DIN 43650 – ISO 4400/6952
Insulation Class F (155 °C)
Enclosure IP65

Conforms to E.U. directives on low voltage and E.M.C.

ADV Spirax-Monnier Automatic Drain Valve

No. Part Material
1 Solenoid body Nylon
2 Timer body ABS
3 Valve body Brass
4 DIN connector ABS

©2022 PT. TOTALITAS TEKNIK INDONESIA. All Rights Reserved.
Chat now!
Scan the code
Hi Totalitas Teknik Indonesia I need more info..