Description
GESTRA NRR 2-52, NRR 2-53 Level Controller & URB 50 Display Unit
Looking for a reliable and precise boiler water level control system? The GESTRA NRR 2-52, NRR 2-53 Level Controllers, and the URB 50 Display Unit offer a powerful, integrated solution for steam boiler water level monitoring, automation, and safety compliance.
Built with German engineering precision, these devices work seamlessly together to ensure fail-safe operations, accurate level regulation, and real-time monitoring in industrial steam and hot water systems.
Product Highlights
GESTRA NRR 2-52 Level Controller
- Designed for use with GESTRA level electrodes (e.g., NRG 26-21, NRG 26-40)
- Monitors and controls the minimum water level in steam boilers
- Failsafe operation and TÜV-tested for use in safety-related applications
- Continuous system self-checks to prevent faults
- Outputs: 4-20 mA signal, relay contacts for alarms or pump control
GESTRA NRR 2-53 Level Controller
- Provides ON/OFF or modulating control of water level
- Works in tandem with NRG series sensors for precision
- Supports 2-position and continuous control modes
-
Enhanced functionality over NRR 2-52 for more complex systems
- Used in both single boiler and cascade boiler systems
GESTRA URB 50 Display Unit
- Digital display for real-time water level indication
- Simple user interface with high-visibility LED indicators
- Displays data from GESTRA level electrodes via CANopen or 4-20 mA
- Wall or panel mountable, IP65-rated front panel
- Alarm and system status visual indicators
Technical Specifications
| Feature | NRR 2-52 | NRR 2-53 | URB 50 Display Unit |
|---|---|---|---|
| Power Supply | 24 V DC / 230 V AC | 24 V DC / 230 V AC | 24 V DC |
| Control Type | ON/OFF | ON/OFF / Modulating | Display Only |
| Inputs | 1x GESTRA Level Probe | Up to 2x Probes | Analog / CANopen |
| Output Signal | 4-20 mA / Relays | 4-20 mA / Relays | Visual Display |
| Mounting | DIN rail | DIN rail | Panel / Wall Mount |
| Protection Class | IP20 | IP20 | IP65 (front panel) |
Technical Data
NRR 2-52, NRR 2-53
Supply voltage
24 VDC +/– 20%
Fuse
external 0.5 A (semi-delay)
Power consumption
5 VA
Connection of level electrode / level transmitter (switch-selectable)
1 input for level electrode NRG 21-.. or NRG 26-21, with 3 poles and screen or
1 analogue input 4-20 mA, e. g. for level transmitter NRGT 26-1, with 2 poles and screen
Supply voltage of level electrode
12 VDC
Input/output
Interface for data exchange with operating & display unit URB 50
Inputs
1 analogue input potentiometer 0 – 1000 Ω, two-wire connection (indication of valve position, only NRR 2-52)
1 analogue input 4-20 mA (steam flowrate) (optional)
1 analogue input 4-20 mA (feedwater flowrate) (optional)
Outputs
NRR 2-52: 2 volt-free change-over contacts,
8 A 250 V AC / 30 V DC cos j = 1 (control valve). 2 volt-free change-over contacts,
8 A 250 V AC / 30 V DC cos j = 1,
De-energizing delay: 3 seconds (MIN/MAX alarm).
NRR 2-53: 4 volt-free change-over contacts, 8 A 250 V AC / 30 V DC cos j = 1,
De-energizing delay: 3 seconds (MIN 1, MIN 2 / MAX 1, MAX 2 alarm)
1 analogue output 4-20 mA, max. load 500 ohm (manipulated variable Y).
Provide inductive loads with RC combinations according to manufacturer’s specification to ensure interference suppression
NRR 2-52, NRR 2-53: 1 analogue output 4-20 mA, max. load 500 ohm (e. g. for actual value indication) (optional)
Indicators and adjustors
1 tri-colour LED indicator (start-up = amber, power ON = green, malfunction = red) 1 code switch with four poles for configuration
Housing
Housing material: base: polycarbonate, black; front: polycarbonate, grey Conductor size: 1 x 4,0 mm² solid per wire or
- x 5 mm2per stranded wire with sleeve to DIN 46228 or
- x 5 mm2per stranded wire with sleeve to DIN 46228 (min. Æ 0.1 mm) terminal strips can be detached separately
Fixing of housing: Mounting clip on supporting rail TH 35, EN 60715
Electrical safety
Pollution degree 2 for installation in control cabinet with protection IP 54, completely insulated
Protection
Housing: IP 40 to EN 60529 Terminal strip: IP 20 to EN 60529
Weight
approx. 0.5 kg
Ambient temperature
when system is switched on: 0° … 55 °C, during operation: –10 … 55°C,
Transport temperature
–20 … +80 °C (<100 hours), defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Storage temperature
–20 … +70 °C, defrosting time of the de-energized equipment before it can be put into operation: 24 hours.
Relative humidity
max. 95%, no moisture condensation
Approvals:
TÜV certificate VdTÜV Bulletin “Water Lever 100” (= Water Level 100): Requirements made on water level limiting & control equipment.
Type approval no. TÜV · WR · XX-427 (see name plate).
UL/cUL (CSA) Approval UL 508 and CSA C22.2 No. 14-13, Standards for Industrial
Control Equipment. File E243189.
URB 50
Supply voltage
24 VDC +/– 20%
Fuse
internal automatic
Power consumption
8 VA
Input / output
Interface for data exchange.
User interface
Analogue resistive touch screen, resolution 480 x 271 pixels, illuminated.
Dimensions
Front panel: 147×107 mm Panel cut-out: 136×96 mm Depth: 56 + 4 mm
Electrical connection
1 connector with 3 poles,
D-SUB connector with 9 poles.
Protection
Front panel: IP 65 to EN 60529 Back: IP 20 to EN 60529
Weight
approx. 1.0 kg
Ambient temperature
when system is switched on: 0 ° … 55 °C, during operation: –10 … 55 °C
Transport temperature
–20 … +80 °C (<100 hours), defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Storage temperature
–20 … +70 °C, defrosting time of the de-energized equipment before it can be put into operation: 24 hours.
Relative humidity
5 – 85 %, no moisture condensation
Scope of supply
NRR 2-52
1 Level controller NRR 2-52
1 Installation manual
NRR 2-53
1 Level controller NRR 2-53
1 Installation manual
URB 50
1 Operating & display unit URB 50 1 Data line L = 5 m
GESTRA NRR 2-52, 2-53, URB 50
Level Controller & Display Unit
GESTRA: The Ultimate Solution for Industrial Steam & Fluid Control Systems
Introduction to GESTRA Level Control Solutions
The GESTRA NRR 2-52 and NRR 2-53 Level Controllers, combined with the URB 50 Display Unit, form a complete and reliable water level control and visualization solution for industrial steam and boiler systems.
Engineered in Germany and trusted worldwide, GESTRA products are designed to deliver precise level control, continuous monitoring, and enhanced boiler safety, even in the most demanding industrial environments.
Why Choose GESTRA NRR Level Controllers & URB 50 Display Unit?
✅ German Engineering Excellence
GESTRA is a globally recognized leader in steam, condensate, and boiler control technology, known for precision and durability.
✅ Accurate & Stable Level Control
The NRR 2-52 and NRR 2-53 ensure precise evaluation of level signals, preventing water level fluctuations that can affect boiler efficiency and safety.
✅ Clear Real-Time Level Display
The URB 50 Display Unit provides continuous, easy-to-read visualization, allowing operators to instantly assess system conditions.
✅ Perfect System Compatibility
Designed for seamless integration with GESTRA level electrodes and probes, ensuring stable and reliable operation.
🔹 GESTRA NRR 2-52 Level Controller
The GESTRA NRR 2-52 is a robust industrial level controller designed for automatic water level control in steam boilers and condensate systems.
Key Features:
-
High-precision signal processing
-
Stable operation under varying load conditions
-
High resistance to electrical interference
-
Easy installation and commissioning
Typical Applications:
-
Steam boilers
-
Condensate tanks
-
Feedwater control systems
🔹 GESTRA NRR 2-53 Level Controller
The GESTRA NRR 2-53 offers advanced control capabilities for complex and high-demand industrial boiler applications.
Key Advantages:
-
Enhanced control accuracy
-
Increased operational reliability
-
Suitable for large-scale and critical systems
-
Long service life with minimal maintenance
🔹 GESTRA URB 50 Display Unit
The GESTRA URB 50 Display Unit is designed to display boiler water level data clearly and continuously, improving operator awareness and system safety.
Main Benefits:
-
Clear, real-time level indication
-
Improved operational transparency
-
Reduced risk of human error
-
Full compatibility with GESTRA controllers
Applications of GESTRA NRR Controllers & URB 50
-
Industrial steam boilers
-
Power generation plants
-
Oil & gas facilities
-
Chemical and petrochemical industries
-
Food & beverage processing
-
Pharmaceutical manufacturing
Technical Advantages of the GESTRA System
-
Precise and reliable level control
-
Continuous monitoring and visualization
-
Fast response to level changes
-
Easy integration with existing boiler systems
-
Reduced downtime and maintenance costs
-
Improved boiler safety and efficiency
Why Buy Original GESTRA NRR & URB Products?
Choosing original GESTRA NRR 2-52, NRR 2-53 Level Controllers and URB 50 Display Unit guarantees:
✔ Manufacturer-certified quality
✔ Compliance with international safety standards
✔ Long-term performance stability
✔ Lower total cost of ownership
⚠️ Non-original products may compromise accuracy, safety, and system reliability.
Frequently Asked Questions (FAQ)
What is the function of GESTRA NRR 2-52 and NRR 2-53?
They are level controllers used to automatically regulate and stabilize water levels in industrial boilers and tanks.
What is the difference between NRR 2-52 and NRR 2-53?
The NRR 2-53 offers enhanced control performance and is ideal for more complex or high-capacity boiler systems.
What does the URB 50 Display Unit do?
The URB 50 provides real-time visual display of water level data, helping operators monitor system conditions accurately.
Are these products compatible with GESTRA level electrodes?
Yes. They are specifically designed for seamless operation with GESTRA level electrodes and probes.
- GESTRA ORG 12 / ORG 22 Detectors – Oil & Turbidity Sensor for Steam Systems
- Gestra PA 46 Blowdown Valve Rapid Action Boiler Blowdown PA 46
- GESTRA BA 28, 29, 210, 211 PN 63 – 320, DN 25 mm (1″) Reactomat Continuous Blowdown Valves
- GESTRA NRS 1-50 Level Switch
- GESTRA NRR 2-52, 2-53 Level Controller, URB 50 Display Unit
- GESTRA NRG 26-21 Level Monitoring
- GESTRA NRGT 26-2 Level Transmitter
- GESTRA Type 5610 / 5801 Mechanical Pressure Regulators
- GESTRA Clorius Self-acting temperature controllers system
- GESTRA BW 31 / 31A Return-Temperature Control Valve