Yokogawa EJX110B
Wireless Differential Pressure Transmitter
Pemancar tekanan absolut dan pengukur nirkabel berkinerja tinggi EJX510B dan EJX530B dilengkapi sensor resonansi silikon kristal tunggal dan cocok untuk mengukur tekanan cairan, gas, atau uap.
EJX510B dan EJX530B tidak hanya mengirimkan variabel proses tetapi juga parameter pengaturan menggunakan sinyal nirkabel.
Pemancar beroperasi dengan baterai internal, dan biaya pemasangan dapat dikurangi karena tidak memerlukan pemasangan kabel secara permanen.
Komunikasi ini mematuhi spesifikasi protokol ISA100.11a.
About OpreX™
OpreX™ is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions.
It consists of categories and families under each category. This product belongs to the OpreX™ Field Instruments family that is aligned under the OpreX™ Measurement category.
Span and Range Limits
Measurement
Span/Range |
kPa | inH2O(/D1) | mbar(/D3) | mmH2O(/D4) | |
F* | Span | 0.1 to 5 | 0.4 to 20 | 1 to 50 | 10 to 500 |
Range | -5 to 5 | -20 to 20 | -50 to 50 | -500 to 500 | |
L* | Span | 0.1 to 10 | 0.4 to 40 | 1 to 100 | 10 to 1000 |
Range | -10 to 10 | -40 to 40 | -100 to 100 | -1000 to 1000 | |
M | Span | 0.5 to 100 | 2 to 400 | 5 to 1000 | 50 to 10000 |
Range | -100 to 100 | -400 to 400 | -1000 to
1000 |
-10000 to
10000 |
|
H |
Span | 2.5 to 500 | 10 to 2000 | 25 to 5000 | 0.025 to 5
kgf/cm2 |
Range | -500 to 500 | -2000 to
2000 |
-5000 to
5000 |
-5 to 5 kgf/cm2 | |
V |
Span | 0.07 to 14
MPa |
10 to 2000
psi |
0.7 to 140
bar |
0.7 to 140
kgf/cm2 |
Range | -0.5 to 14
MPa |
-71 to 2000
psi |
-5 to 140 bar | -5 to 140
kgf/cm2 |
Reference Accuracy of Calibrated Span
Measurement span | F | |
Reference
accuracy |
X ≤ span | ±0.04% of Span |
X > span | ±(0.015+0.01 URL/span)% of Span | |
X | 2 kPa (8 inH2O) | |
URL (upper range limit) | 5 kPa (20 inH2O) |
Measurement span | M | |
Reference
accuracy |
X ≤ span | ±0.04% of Span |
X > span | ±(0.002+0.0019 URL/span)% of Span | |
X | 5 kPa (20 inH2O) | |
URL (upper range limit) | 100 kPa (400 inH2O) |
Measurement span | H | |
Reference
accuracy |
X ≤ span | ±0.04% of Span |
X > span | ±(0.005+0.0049 URL/span)% of Span | |
X | 70 kPa (280 inH2O) | |
URL (upper range limit) | 500 kPa (2000 inH2O) |
Measurement span | V | |
Reference
accuracy |
X ≤ span | ±0.04% of Span |
X > span | ±(0.005+0.00125 URL/span)% of
Span |
|
X | 500 kPa (2000 inH2O) | |
URL (upper range limit) | 14 MPa (2000 psi) |