Diskripsi Produk
The AVF250 Series flowmeter is commonly used in location that required on-site analog flow indication. The meter accurately measures small volumes / wide ranges of liquids, gases and steam
Fitur
- 5 Digit Flowrate & 8 Digit Totalizer
- Local indication without auxiliary power
- 4-20 mA and scale pulse output
- Low pressure loss in gas and steam application
- Damper for Gas / Steam application
- Consistent overall length
- Heating jacket design
- Intrinsically safe & explosion proof for hazardous area
Spesifikasi
Size | : | 15,20,25,40,50,65,80,100,125,150,200 mm |
Measuring Range | : | Liquid -1~200000 L/hr |
: | Gas -0.03~3000 m3/hr | |
Turndown Ratio | : | 10:1 (20:1 Optional) |
Accuracy | : | +/-1.6% (Standard) |
: | +/-1.0% (Optional) | |
Repeatability | : | +/-0.5% FS |
Material | ||
Tube & Float | : | Stainless Steel 304 |
: | Stainless Steel 316 | |
: | Stainless Steel 316L | |
: | Stainless Steel + PTFE Liner | |
Standard Pressure | : | 40 kgf/cm2 (15-50 mm) |
: | 16 kgf/cm2 (65-200 mm) | |
Temperature | : | -25~200 °C (Standard) |
: | -25~100 °C (LCD Display) | |
: | 0~80 °C (PTFE Liner) | |
: | -80~400 °C (Optional) | |
Flange Type | : | JIS 10K / JIS 20K / JIS 40K |
ANSI 150# / ANSI 300# / ANSI 600# | ||
DIN PN10 / PN16 / PN25 / PN40 | ||
Fluid Viscosity | : | 300 cP Max. |
Communication | : | RS485 (MODBUS Protocol) |
: | HART signal (Compatible) |
Local Display | : | Mechanical Indicator (Standard) |
Digit Display | : | 5 Digit Flowrate |
: | 8 Digit Totalizer | |
Current Output | : | 4-20 mA (2 wires) |
Load | : | Max. 600 Ω |
Pulse Output | : | Open collector (Scaled pulse) |
Rating | : | 3-30 VDC, 100 mA Max. |
Data Storage | : | Operation parameters and totalizer |
figures are stored by EEPROM for more | ||
than 10 years | ||
Alarm Output | : | 2 Point (Open collector) |
Rating | : | 3-30 VDC, 100 mA Max. |
Keypad | : | 3 Internal keys for programming |
and display control | ||
Ambient Temperature | : | -25~60 °C |
Protection Class | : | IP65 |
: | Intrinsically Safe, Eex ia IIC T5 | |
: | Explosion Proof, Ex d IIC T6 | |
Housing Material | : | Aluminum Alloy |
Cable Entry | : | Standard: M20 Option: 1/2″ NPTF |
Pressure Loss | : | 0.07-0.7 kgf/cm2 |
Power Supply | : | 12-36 VDC |
: | Ni-MH Battery (3 years working hours) |